Planning a safe DC cable run
Correct cable sizing reduces voltage drop, unwanted heat, and wasted energy. Low-voltage DC systems are especially sensitive to this because the same power needs more current than in a mains circuit, and current is what causes losses in the cable.
What you need to know
- System voltage (12 V, 24 V or 48 V)
- Current (amps), or the inverter size in watts if you’re sizing an inverter cable
- One-way cable length (the run from source to load, in metres)
- Target voltage drop (commonly 3% or less; 1-2% for sensitive equipment, and 2% or less for inverters)
The calculation
Current flows out and back, so the circuit length is twice the one-way distance.
Minimum cross-section (mm²) = (2 × length × current × 0.0172) ÷ allowable voltage drop (V)
The 0.0172 figure is the resistivity of copper in Ω·mm²/m. The allowable voltage drop in volts is the system voltage × your target percentage.
Example: a 12 V circuit carrying 20 A over 5 m one-way, with a 3% target (0.36 V). (2 × 5 × 20 × 0.0172) ÷ 0.36 = 9.6 mm², so choose 10 mm² cable.
Assumptions: The calculator assumes pure copper cable. Copper-clad aluminium (CCA) and aluminium cable have higher resistance and carry less current, so they need a larger size. Avoid CCA for battery, inverter and other high-current runs. For inverters, about 15% is added for inverter losses.
Also check
- Current rating: The cable must safely carry the full load current for its insulation type, installation method, ambient temperature, and whether it is bundled with other cables. Use whichever requirement, voltage drop or current rating, calls for the larger cable.
- Protection: Fit a fuse or breaker rated to protect the cable, positioned as close to the power source as practical. Use the [DC fuse size calculator] to choose one.
- Terminations: Lugs, connectors, and crimps must suit the cable size and current.
Important to know
These results are a planning guide, not a final electrical design. Confirm the final cable size, insulation rating, protection, and installation method against the cable and equipment datasheets and the standards that apply where you live, and have the installation checked by a qualified installer.